Technical Data - Face Fix Girder Truss Hanger - SDS Installation

HGUQ

Technical Data

Dimensions

product.image_with_dim.alt - HGUQ - Face Fix Girder Truss Hanger - SDS Installation
References Joist Size Dimensions [mm] Header holes Joist holes
Width A B C D F t Ø6.4 [mm] Ø6.4 [mm]
HGUQ180/105SCR 2x47 105 180 100 54.5 102.5 2.5 26 8
HGUQ180/120SCR 3x35 120 180 100 54.5 102.5 2.5 26 8
HGUQ180/155SCR 3x47 155 180 100 54.5 102.5 2.5 26 8
HGUQ180/202SCR 4x47 202 180 100 54.5 102.5 2.5 26 8

HGUQ Installed with SDS Screws - Characteristic Capacity

HGUQ Installed with SDS Screws - Characteristic Capacity - HGUQ - Face Fix Girder Truss Hanger - SDS Installation
product.image_with_dim.alt - HGUQ - Face Fix Girder Truss Hanger - SDS Installation
References Fasteners Characteristic capacity - Timber TR26/C27 [kN] Safe Working Load [kN]
Header Joist
R1,k
R2,k R1,SWL,Medium Term R1,SWL,Long term R2,SWL,Short term
Qty Qty SDS25312 SDS25212 TR26 header TR26 header TR26 Joist
SDS25312
SDS25312
SDS25212
HGUQ180/105SCR 26 8 45.5 20.7 24.4 21.3 10.4
HGUQ180/120SCR 26 8 45.5 20.7 24.4 21.3 10.4
HGUQ180/155SCR 26 8 45.5 20.7 24.4 21.3 10.4
HGUQ180/202SCR 26 8 45.5 20.7 24.4 21.3 10.4

1. Safe working loads have been determined in accordance with BS 5268 and are based on TR26/C27 graded timbers.
2. Characteristic values have been determined in accordance with ETAG015, TR016 and EN 14358 for use with Eurocode 5. Values are based on TR26/C27 graded timbers.
3. Uplift values have been determined by calculation in accordance with Eurocode 5. Values are based on TR26/C27 graded timbers.
4. Hanger supplied with SDS25312 (89mm) and SDS25212 (63mm) SDS screws.