Technical Data - Framing Anchors

A35

Technical Data

Dimensions

product.image_with_dim.alt - A35 - Framing Anchors
References Dimensions [mm]
A B C E E1 Thick.
A35 35 115 35 40 75 1.2

Connection Type 2

Connection Type 2 - A35 - Framing Anchors
References Fasteners Safe Working Loads
(Long Term - C16 Timber) [kN]
Characteristic Loads
(C24 Timber) [kN]
Qty Specification F1 F2 F1 F2
A35 12 3.75 x 30 1.3 1.46 1.33 0.89

Connection Type 3

Connection Type 3 - A35 - Framing Anchors
References Fasteners Safe Working Loads
(Long Term - C16 Timber) [kN]
Characteristic Loads
(C24 Timber) [kN]
Qty Specification F1 F2 F3 F1 (Single) F1 (Pair) F2 F3
A35 9 3.75 x 30 0.98 0.64 0.98 0.6 5.26 0.59 0.46

Connection Type 4

Connection Type 4 - A35 - Framing Anchors
References Fasteners Safe Working Loads
(Long Term - C16 Timber) [kN]
Characteristic Loads
(C24 Timber) [kN]
Qty Specification F1 F2 F3 F(Single) F1 (Pair) F2 F3
A35 12 3.75 x 30 0.98 0.98 0.57 1.03 5.26 1.14 0.84

Framing anchors must be installed diagonally opposite each other for the higher characteristic capacities for a pair of connectors to be applicable in installations 3 and 4