Technical Data - Masonry Hanger for Solid Joists

JHM

Technical Data

Dimensions

product.image_with_dim.alt - JHM - Masonry Hanger for Solid Joists
References Joist Size [mm] Hanger Dimensions [mm] Joist holes
Width Height A B C D E F t Ø4
JHM100/38 35 100 38 100 64 64 75 75 2 2
JHM125/38 35 125 38 125 64 64 75 75 2 2
JHM150/38 35 150 38 140 64 64 75 75 2 2
JHM175/38 35 175 38 165 64 64 75 75 2 2
JHM200/38 35 200 38 190 64 64 75 75 2 2
JHM225/38 35 225 38 215 64 64 75 75 2 2
JHM250/38 35 250 38 240 64 64 75 75 2 2
JHM125/44 44 125 44 125 64 64 75 75 2 2
JHM150/44 44 150 44 140 64 64 75 75 2 2
JHM175/44 44 175 44 165 64 64 75 75 2 2
JHM200/44 44 200 44 190 64 64 75 75 2 2
JHM225/44 44 225 44 215 64 64 75 75 2 2
JHM250/44 44 250 44 240 64 64 75 75 2 2
JHM100/47 47 100 47 100 64 64 75 75 2 2
JHM125/47 47 125 47 125 64 64 75 75 2 2
JHM150/47 47 150 47 140 64 64 75 75 2 2
JHM175/47 47 175 47 165 64 64 75 75 2 2
JHM200/47 47 200 47 190 64 64 75 75 2 2
JHM225/47 47 225 47 215 64 64 75 75 2 2
JHM250/47 47 250 47 240 64 64 75 75 2 2
JHM100/50 50 100 50 100 64 64 75 75 2 2
JHM125/50 50 125 50 125 64 64 75 75 2 2
JHM150/50 50 150 50 140 64 64 75 75 2 2
JHM175/50 50 175 50 165 64 64 75 75 2 2
JHM200/50 50 200 50 190 64 64 75 75 2 2
JHM225/50 50 225 50 215 64 64 75 75 2 2
JHM250/50 50 250 50 240 64 64 75 75 2 2
JHM125/63 63 125 63 125 64 64 75 75 2 2
JHM150/63 63 150 63 140 64 64 75 75 2 2
JHM175/63 63 175 63 165 64 64 75 75 2 2
JHM200/63 63 200 63 190 64 64 75 75 2 2
JHM225/63 63 225 63 215 64 64 75 75 2 2
JHM250/63 63 250 63 240 64 64 75 75 2 2
JHM100/75 2x35 or 75 100 75 100 64 64 75 75 2 2
JHM125/75 2x35 or 75 125 75 125 64 64 75 75 2 2
JHM150/75 2x35 or 75 150 75 140 64 64 75 75 2 2
JHM175/75 2x35 or 75 175 75 165 64 64 75 75 2 2
JHM200/75 2x35 or 75 200 75 190 64 64 75 75 2 2
JHM225/75 2x35 or 75 225 75 215 64 64 75 75 2 2
JHM250/75 2x35 or 75 250 75 240 64 64 75 75 2 2
JHM100/91 2x44 or 91 100 91 100 64 64 75 75 2 2
JHM125/91 2x44 or 91 125 91 125 64 64 75 75 2 2
JHM150/91 2x44 or 91 150 91 140 64 64 75 75 2 2
JHM175/91 2x44 or 91 175 91 165 64 64 75 75 2 2
JHM200/91 2x44 or 91 200 91 190 64 64 75 75 2 2
JHM225/91 2x44 or 91 225 91 215 64 64 75 75 2 2
JHM250/91 2x44 or 91 250 91 240 64 64 75 75 2 2
JHM100/100 2x50 or 100 100 100 100 64 64 75 75 2 2
JHM125/100 2x50 or 100 125 100 125 64 64 75 75 2 2
JHM150/100 2x50 or 100 150 100 140 64 64 75 75 2 2
JHM175/100 2x50 or 100 175 100 165 64 64 75 75 2 2
JHM200/100 2x50 or 100 200 100 190 64 64 75 75 2 2
JHM225/100 2x50 or 100 225 100 215 64 64 75 75 2 2
JHM250/100 2x50 or 100 250 100 240 64 64 75 75 2 2
JHM125/125 2x63 125 125 125 64 64 75 75 2 2
JHM225/125 2x63 225 125 215 64 64 75 75 2 2
JHM250/125 2x63 250 125 240 64 64 75 75 2 2
JHM300/125 2x63 300 125 290 64 64 75 75 2 2
JHM175/150 3x50 or 2x75 175 150 165 64 64 75 75 2 2
JHM225/150 3x50 or 2x75 225 150 215 64 64 75 75 2 2
JHM250/150 3x50 or 2x75 250 150 240 64 64 75 75 2 2
JHM300/150 3x50 or 2x75 300 150 290 64 64 75 75 2 2
JHM - - - - 64 64 75 75 2 2
Spec JHMSK - - - - - - 75 75 2.5 2

Characteristic Values

Characteristic Values - JHM - Masonry Hanger for Solid Joists
References Joist Fasteners Characteristic Capacities [kN] Safe Working Load [kN]
Qty Type R1,k R2,k R1,SWL R2,SWL,Short Term
2.8N/mm² Solid AAC 3.5N/mm² Solid LAC 7.0N/mm² Solid DAC 2.8N/mm² Solid AAC 3.5N/mm² Solid LAC 7.0N/mm² Solid DAC
JHM 2 N3.75x30 10.5 12.8 20 1.8 5.2 6.4 10 1

JHM Skewed

JHM Skewed - JHM - Masonry Hanger for Solid Joists
References Joist Fasteners Safe Working Load [kN]
Qty Type R1,SWL R2,SWL,Short Term
2.8N/mm² Solid AAC 3.5N/mm² Solid LAC 7.0N/mm² Solid DAC
Spec JHMSK 4 3.75x30 5 5.1 5.1 1

1. Maximum skew 45º

JHM Shot fired to steel Girder

JHM Shot fired to steel Girder - JHM - Masonry Hanger for Solid Joists
References Fasteners Safe Working Load [kN]
Header Joist R1,SWL,Long Term
Qty Type Qty Type
JHM 4 Shot fire pins 2 N3.75x30 5.1

1.The above Safe Working Loads are based upon product tests using four No. Hilti 12mm X-EDNI steel pins fired through holes provided in the top flange of the hangers onto 4mm thick steel plate. Other pins may be used provided similar structural performance is verified by the pin manufacturer. Pin Head size must be sufficient to prevent pull through during loading.

2.The designer must ensure that the steel support member will support the imposed loads.

3.Install shot-fired pins in accordance with manufacturer’s instructions.