Technical Data - Reinforced angle brackets for CLT

ABR255

Technical Data

Dimensions

Dimensions - ABR255 - Reinforced angle brackets for CLT
product.image_with_dim.alt - ABR255 - Reinforced angle brackets for CLT
References Dimensions [mm] Holes [mm]
A B C Th. leg A Flange B
Nails or screws Bolts Nails or screws Bolts
ABR255 120 100 255 3 52 Ø5 2 Ø14 41 Ø5 4 Ø14

Timber to timber connexion with 1 bracket - Full nailing

Timber to timber connexion with 1 bracket - Full nailing - ABR255 - Reinforced angle brackets for CLT
product.image_with_dim.alt - ABR255 - Reinforced angle brackets for CLT
References Fasteners Characteristic Capacities [kN]
Leg B (Nails) Aile C (Nails) Tension (F1) Shear (F2=F3)
CNA4,0x50 CNA4,0x50
ABR255 52 Ø4 41 Ø4 18.8 45.9

The values given in the table can only be used when the vertical part can't rotate.

Timber to timber connexion with 1 bracket - Partial nailing

Timber to timber connexion with 1 bracket - Partial nailing - ABR255 - Reinforced angle brackets for CLT
product.image_with_dim.alt - ABR255 - Reinforced angle brackets for CLT
References Fasteners Characteristic Capacities [kN]
Leg B (Nails) Leg C (Nails) Tension (F1) Shear (F2=F3)
CNA4,0x50 CNA4,0x50
ABR255 30 Ø4 23 Ø4 15.9 38

The values given in the table can only be used when the vertical part can't rotate.

Timber to concrete connexion with 1 bracket - Full nailing

Timber to concrete connexion with 1 bracket - Full nailing - ABR255 - Reinforced angle brackets for CLT
product.image_with_dim.alt - ABR255 - Reinforced angle brackets for CLT
References Fasteners Characteristic Capacities [kN]
Leg B (Nails) Leg C (Bolts) Tension (F1) Shear (F2=F3)
CNA4,0x50 CNA4,0x50
ABR255 52 Ø4 2 Ø12 20 37.7

The values given in the table can only be used when the vertical part can't rotate.

The anchor capacities must be checked separatly by multiplying the F1 load by a factor 1.1 and F2 load by a factor of 1.

Timber to concrete connexion with 1 bracket - Partial nailing

Timber to concrete connexion with 1 bracket - Partial nailing - ABR255 - Reinforced angle brackets for CLT
product.image_with_dim.alt - ABR255 - Reinforced angle brackets for CLT
References Fasteners Characteristic Capacities [kN]
Leg B (Nails) Leg C (Bolts) Tension (F1) Shear (F2=F3)
CNA4,0x50 CNA4,0x50
ABR255 30 Ø4 2 Ø12 20 28.3

The values given in the table can only be used when the vertical part can't rotate.

The anchor capacities must be checked separatly by multiplying the F1 load by a factor 1.1 and F2 load by a factor of 1.