Technical Data - Ridge Rafter Connector

RR

Technical Data

RR Safe Working Loads

RR Safe Working Loads - RR - Ridge Rafter Connector
References Min. joist size Dimensions Fasteners Safe Working Loads [kN]
A D Support Joist
Qty Specification Qty Specification
RR 38 x 95 38 102 4 3.75 x 30mm 4 3.75 x 30mm 1.4
RR47 45 x 95 47 112 4 3.75 x 30mm 4 3.75 x 30mm 1.4

RR Characteristic Loads

References Min. joist size Dimensions Fasteners Characteristic Download [kN]
A D Support Joist
Qty Specification Qty Specification
RR 38 x 95 38 102 4 3.75 x 30mm 4 3.75 x 30mm 0.62
RR47 45 x 95 47 112 4 3.75 x 30mm 4 3.75 x 30mm 0.62