ABR

Reinforced Angle Bracket

Reinforced angle brackets are suitable for structural applications in framing and timber framed houses as well as light gauge steel construction.

CE Marking
ETA
Service class 2
Indoor
Electrogalvanized steel Z275

Product Details

Features

Material

  • Galvanized steel S250GD + Z275 according to NF EN 10346.

Benefits

  • Reinforcing ribs provide enhanced performance.

 

Application

Suitable On

  • Supporting member: solid wood, glued-laminated wood, concrete, steel, etc.
  • Supported member: solid wood, composite lumber, glued-laminated wood, triangular trusses, profiles, etc.

When to Use

  • Fastening of small trusses.
  • Cladding plates, cladding uprights.
  • Rafter anchors, cantilevers, headers, etc.
  • Light gauge steel.

Technical Data

Dimensions

Product Dimensions

References Tun / DB nr. NOB nr.
ABR7015155316845554233
ABR9020124153141327099
ABR10525155316445540683

Combined loads:

 

Installation

Installation

Fixing

On wood:

  • CNA annular ring-shank nails dia. 4.0 x 35 or dia. 4.0 x 50 mm.
  • CSA screws dia. 5.0 x 35 mm or CSA screws dia. 5.0 x 40 mm.
  • Bolts.
  • LAG screws.

On concrete:
Concrete substrate

  • Mechanical anchor: WA M10-78/5 OR WA M12-104/5 pin.
  • Chemical anchor: AT-HP resin + LMAS M10-120/25 or LMAS M12-150/35 threaded rod.

Hollow masonry substrate:

  • Chemical anchor: AT-HP or POLY-GP resin + LMAS M12-150/35 threaded rod + SH M16-130 screen.

On steel:

  • Bolts.

Technical Notes

Technical Notes

F1: tensile force in the central axis of the angle-bracket
Particular situation of a fastening with only one angle-bracket:

  • If the overall structure prevents the rotation of the purlin or the post, the tensile strength is equal to half of the given value for two angle-brackets.
  • Otherwise, the connection resistance depends on the « f » distance between the vertical contact surface and the point of load application.

F2 and F3: shear lateral force
Particular situation of a connection with only one angle-bracket:

  • The resistance value to consider is equal to half of the one given for two angle-brackets.

F4 and F5: transversal force directed towards or opposite the angle-bracket

  • The connection resistance depends on the « e » distance between the base of the angle-bracket and the point of load application.
  • To consult corresponding loads, contact us.

Only F1, F2 and F3 forces for connections with 2 angle-brackets are present on this sheet.
For more information, contact us.