Installation
  • Tie should be fixed into brickwork, blockwork or stone.
  • Tie must be installed horizontally.
  • Position the tie so that the mortar end is located in the bed joint of the new leaf of brickwork or blockwork.
  • Drill a hole for the wall plug (diameter 10 x 45mm) and insert the nylon wall plug.
  • Slide the neoprene 'O' ring onto the tie and screw into the plug.
  • Build the tie into the new leaf of brickwork or blockwork, ensuring that it is surrounded by mortar.