Technical Data - Large Reinforced Angle Brackets

E9S/2.5

Technical Data

Product Dimensions

Product Dimensions - E9S/2.5 - Large Reinforced Angle Brackets
product.image_with_dim.alt - E9S/2.5 - Large Reinforced Angle Brackets
References Product Dimensions [mm] Joist Holes flange B
A B C t Ø5 Ø11 Ø11x34 Ø5 Ø11
E9S/2,5 150 90 65 2.5 14 1 1 8 1

Wood/wood connection beam/beam type - assembly with 2 angle brackets

Wood/wood connection beam/beam type - assembly with 2 angle brackets - E9S/2.5 - Large Reinforced Angle Brackets
Wood/wood connection beam/beam type - assembly with 2 angle brackets - E9S/2.5 - Large Reinforced Angle Brackets
product.image_with_dim.alt - E9S/2.5 - Large Reinforced Angle Brackets
References Simplified product capacities - Timber beam to timber beam
Number of Fasteners Simplified characteristic capacities - Timber C24 - 2 angle brackets per connection [kN]
Joist Flange B R1.k* R2.k = R3.k
Qty Qty CNA4.0x35 CNA4.0x50 CNA4.0x35 CNA4.0x50
E9S/2,5 12 8 4.7 7.9 8.8 11.8

* The published characteristic capacity is based on short term load duration and service class 2 according to EC5 (EN 1995) – kmod = 0.9. For other load duration and service class, please refer to the ETA to get more accurate capacities.

To obtain the resistance values for a single bracket, the values in the above table should be divided by two, provided that the supported beam is locked in rotation. Please consult our ETA-06/0106 if the beam is free to rotate.

Wood/wood connection post/beam type - assembly with 2 angle brackets

Wood/wood connection post/beam type - assembly with 2 angle brackets - E9S/2.5 - Large Reinforced Angle Brackets
Wood/wood connection post/beam type - assembly with 2 angle brackets - E9S/2.5 - Large Reinforced Angle Brackets
product.image_with_dim.alt - E9S/2.5 - Large Reinforced Angle Brackets
References Product capacities - Timber beam to timber post
Number of Fasteners Characteristic capacities - Timber C24 - 2 angle brackets per connection [kN]
Joist Flange B R1.k R2.k = R3.k
Qty Qty CNA4.0x35 CNA4.0x50 CNA4.0x35 CNA4.0x50
E9S/2,5 10 8 2.8 4.6 7 9.6

To obtain the resistance values for a single bracket, the values in the above table should be divided by two, provided that the supported beam is locked in rotation. Please consult our ETA-06/0106 if the beam is free to rotate.